CT-302 Bakelite Type Thermometer


Description
The CT-302 features a bakelite terminal box design, offering excellent insulation and corrosion resistance, making it suitable for temperature monitoring in industries such as chemical processing, food processing, and pharmaceuticals. Equipped with a corrosion-resistant protective sleeve, it provides additional protection and extends its service life.
Specifications
Sensing Element
- Thermocouples: Types K, T, J, R, S, and B
- Platinum resistors: PT100, PT1000, PT500
Accuracy Class
- Class A, Class B, 1/10 DIN, 1/5 DIN, 1/3 DIN (select according to application)
Wiring Method
- Thermocouple: 2-wire
- PT100: 3-wire
Temperature Range (depending on the sensing element)
- Type K thermocouple: Approximately –50°C to +1200°C
- Type T thermocouple: Approximately –250°C to +350°C
- J-type thermocouple: approx. –40°C ~ +750°C
- R/S/B type thermocouple: approx. +600°C ~ +1600°C
- PT100: –200°C ~ +500°C (depending on package and wire material)
Probe Appearance and Dimensions
- Standard rod-shaped probe diameters: Φ3.2, Φ4.8, Φ5, Φ6.3 mm, Φ9.5 mm (custom sizes available)
- Probe length: can be specified as needed (e.g., 30mm, 50mm, 100mm and above)
Terminal Box
- Material: Bakelite
Selection of Probe Material
| Material | Description |
|---|---|
| 304SS | Stainless steel for general industrial use, with excellent corrosion resistance. |
| 316SS | High corrosion-resistant stainless steel, suitable for chemical or humid environments. |
| 310SS | High-temperature stainless steel with excellent heat resistance. |
| P4 | High-purity ferritic alloy, resistant to high temperatures and corrosion. |
| INCONEL | Ultra-high temperature nickel-based alloy, resistant to oxidation and acidic environments. |
| Hastelloy-C | High corrosion resistant nickel-chromium alloy, resistant to strong acid environments. |
| Hastelloy-B | High acid resistance nickel-chromium-molybdenum alloy, suitable for extremely acidic environments. |
Application Examples
- Chemical process temperature monitoring.
- Food processing temperature monitoring.
- Temperature monitoring in the pharmaceutical industry.
- Temperature monitoring of automated equipment.
- Temperature measurement inside the control box.
Further Reading
- Sensing accuracy and error calculation method
Resistance thermometer accuracy table and calculation formula
- Thermocouple accuracy and power meter
- Product Classification by Appearance
- Temperature calibration laboratory information
Contact Information
For quotes, product selection advice, or technical assistance, please contact us through the following methods:
- Tel:07-3531378
- LINE@:@oneway3281
- Email:sales@oneway.com.tw


Tech Docs
FAQ